- Use the structure factor equation to calculate the F2
(intensity) values for (i) the 200-reflection, and (ii) the 100-reflection from
sodium chloride. You have already been given a sample calculation for the
111-reflection,Calculating the Intensity of
Diffraction Using the Structure Factor Equation, and all the information
that you need is contained within this example. In the case of the
100-reflection there is something odd about the answer and you should try to
explain this.
Sodium chloride (NaCl) is a face centred cubic structure
with a unit cell a-spacing of 5.638 Å. The structure and fractional
coordinates for the 4 Na and 4 Cl ions are given in the figure below.
Answer:
(i) Calculation of the intensity of the 200 reflection
The trigonometric form of the Structure Factor equation is:
| | | | | |
| | | | |
| | | | |
F(S) = Sn
fn cos {360 (hx + ky + lz)} +
iSn
fn sin {360 (hx + ky + lz)} (in
degrees) |
(1) Using Crystallography and Bragg's law
The d-spacing for the 200 reflection is required. The
formula for d for cubic crystals is:
| | | | | |
| | | | |
| | | | |
dhkl
= a/Ö(h2 +
k2 + l2 ) |
For h,k,l = 2,0,0 we have
| | | | | |
| | | | |
| | | | |
d200 =
5.638/Ö(22
+ 02 + 02 ) =
5.638/Ö4 = 2.819
Å |
From Bragg's law
hence
| | | | | |
| | | | |
| | |
sin q/l =
1/2d = 1/(2 ´ 2.819) = 0.177
Å-1 |
(2) Working out the atomic scattering factors (fn) needed:
From the International Crystallographic Tables, the atomic scattering
factors for Na+ and Cl- in the vicinity of 0.177 Å are:
| sin q/l |
0.15 | 0.20 |
| fNa+ |
9.035 |
8.39 |
| fCl-
|
14.12 |
12.20 |
The form factor is a smooth function, so it is reasonable to
interplolate between the values given. This results in:
| sin q/l |
0.15 |
0.177 |
0.20 |
| fNa+ | 9.035 |
8.69 | 8.39 |
| fCl-
| 14.12 |
13.08 | 12.20 |
(3) Working out the cosine part of F111
Since k = l = 0, only the h term is required in the structure factor equation.
Inserting the appropriate f values, coordinates and retaining only
h = 2 gives:
| Sn
fn cos{360 (hx + ky + lz)} |
= |
|
8.69 cos {360 (2 ´ 0)} |
| |
|
+ |
8.69 cos {360 (2 ´ 0)} |
| |
|
+ |
8.69 cos {360 (2 ´ 1/2)} |
| |
|
+ |
8.69 cos {360 (2 ´ 1/2)} |
| |
|
+ |
13.08 cos {360 (2 ´ 1/2)} |
| |
|
+ |
13.08 cos {360 (2 ´ 0)} |
| |
|
+ |
13.08 cos {360 (2 ´ 0)} |
| |
|
+ |
13.08 cos {360 (2 ´ 1/2)} |
| |
= |
|
8.69 cos 0 + 8.69 cos 0 + 8.69 cos 360 + 8.69 cos 360 |
| |
|
+ |
13.08 cos 360 + 13.08 cos 0 + 13.08 cos 0 + 13.08 cos 360 |
| |
= |
|
8.69 + 8.69 + 8.69 + 8.69 + 13.08 + 13.08 + 13.08 + 13.08 |
| |
= |
|
87.08 |
(4) Working out the sine part of F111
Similarly, only the h term needs to be considered:
| Sn
fn sin {2p (hx + ky
+ lz)} |
= |
|
8.69 sin {360(2 ´ 0)} |
| |
|
+ |
8.69 sin {360(2 ´ 0)} |
| |
|
+ |
8.69 sin {360(2 ´ 1/2)} |
| |
|
+ |
8.69 sin {360(2 ´ 1/2)} |
| |
|
+ |
13.08 sin {360(2 ´ 1/2)} |
| |
|
+ | 13.08 sin {360(2 ´ 0)} |
| |
|
+ |
13.08 sin {360(2 ´ 0)} |
| |
|
+ |
13.08 sin {360(2 ´ 1/2)} |
| |
= |
|
8.69 sin 0 + 8.69 sin 0 + 8.69 sin
360 + 8.69 sin 360 |
| |
|
+ |
13.08 sin 360 + 13.97 sin 0 + 13.97 sin 0 + 13.97 sin 360 |
| |
= |
| 0 + 0 + 0 + 0 + 0 + 0 + 0 + 0 |
| |
= |
|
0 |
(5) Combining the cosine and sine parts of F200 gives:
(6) The intensity I200
The intensity I is the square of the amplitude F:
| | | | | |
| | | | |
| | | | |
I200 = F2002 = 7583 units
|
(ii) Calculation of the intensity of the 100 reflection
To calculate the intensity the procedure above can be followed. This is very tedious! Is there a shortcut?
YES! For the intensity to be non-zero the sum of the cosine and sine terms must be non-zero.
Since it is the 100 reflection that is required, again only the first term is needed. In the expressions
given above, the 2 is replaced by 1, thus terms like:
cos {360 (2 ´ 0)} |
become:
cos {360 (1 ´ 0)} |
For the cosine terms the values will consist of either cos 0 or cos 180 i.e. 1 and -1
respectively. Since there are equal numbers of each term the sum will be identically zero.
Similarly for the sine terms, the terms will be either sin 0 or sin 180, both of which are zero
Hence the sine terms are also zero. Thus the structure factor and hence the intensity are both zero.
Further since cos 180n = -1 (n odd) and +1 (n=0 or even), the same situation will arise for all the reflections of
the type h00 (h odd) and these relections will be absent. Exactly the same arguments apply to reflections of the type 0k0 and 00l,
thus reflections with k odd will be absent for 0k0 and reflections with l odd will be absent for 0l0.
Physically, this corresponds to destructive
interference by neighbouring ions (of the same type).
- Work out the multiplicity allowance factor needed for the 200-reflection.
For the multiplicity of the 200 reflection, the equivalent planes are:
200 and -200
Since a "bar zero" index is the same as a "zero" index, these are the only two planes. Hence j= 2 for 200.
- Calculate the Polarisation allowance factor needed for the 200-reflection.
(1) Working out the angles q,
2q :
From above:
Assuming that Copper K-alpha radiation with a wavelength of 1.54 Å is used and
inserting into Bragg's law gives:
| | | | | |
| | | | |
| | | | |
1.54 | = 2
´ 2.819 ´
sinq |
| | | | | |
| | | | |
| | | | |
sinq |
= 0.273 |
| | | | | |
| | | | |
| | | | |
q |
=
sin-1(0.273) = 15.85° |
| | | | | |
| | | | |
| | | | |
2q |
= 31.70° |
(2) Calculating P200 :
For the laboratory powder diffractometer we use the formula of Case (3):
| 2q |
= 31.70° |
| cos (2q) |
= 0.851 |
| cos2 (2q) |
= 0.724 |
| 1 + cos2 (2q) |
= 1.724
|
| P200 =
(1 + cos2 (2q ))/2 |
= 0.862 |
So polarisation produces a reduction in intensity to 86% in the case of the 200
reflection.
- Calculate the Lorentz allowance factor needed for the 200-reflection.
For the NaCl-200 reflection, and using the value for theta already
obtained in the polarisation calculation:
| | | | | |
| | | | |
q |
= 15.85° |
| | | | | |
| | | | |
sin q |
= 0.273 |
| | | | | |
| | | | |
sin2q |
= 0.0746 |
| | | | | |
| | | | |
cos q |
= 0.962 |
| | | | | |
| | | | |
sin2q
cos q |
= 0.0718 |
| | | | | |
| | | | |
L = 1/sin2q
cos q |
= 13.94 |
- The next step is to bring together the F2 value and 3 allowance
factors determined above for a prediction of the intensity ratio
I111/ I200 .
Now:
| I111 |
|
j111 P111
L111 F1112 |
|
(8) (0.894) (18.39) (398) |
|
52347 |
|
¾¾ |
= |
¾¾¾¾¾¾¾¾¾
|
= |
¾¾¾¾¾¾¾¾¾
|
= |
¾¾ |
= |
|
0.287 |
| I200
|
|
j200 P200
L200 F2002 |
|
(2) (0.862) (13.94) (7583) |
|
182239 |
- In the model answer that you will eventually receive for this assignment,
an actual experimentally measured ratio,
I111/ I200 , will be presented to
you. However, for the moment I would like to present you with a hypothetical
situation for the purposes of this question. Imagine someone informs you that
s/he has measured the ratio
I111/ I200 for
sodium chloride but you have no details of the experiment and you suspect that
the quality of the measurement is far from good. True to your suspicions the
measured ratio differs significantly from your prediction. I would like you to
think creatively as to what plausible factors (additional to j,
P, L) might be the cause of this disagreement. I only want brief
answers, such as a one-phrase/sentence explanation for each factor you dream
up. List them in order of severity.
It is hoped that, with the combination of your imagination and all the course
material you have received so far, you should have no difficulty devising some
5-10 plausible factors; perhaps you might even come up with more than 10.
- Human error The calculations for the intensities are long and intricate,
a slip of the calculator will result in an incorrect answer. (This applies to both me and the
other experimentalist!) There are all sorts of other possibilities in here including
measuring the wrong reflection and getting one or other of the correction factors wrong.
- Texture For NaCL it is possible to grow large single crystals quite easily, thus it
would be possible to produce a sample with preferred orientation.
- Impure sample If the sample is not single phase, then the impurity/ies could have diffraction lines
at the same position as the NaCL lines, so distorting the measured intensities.
- Temperature If the measurements are made at different temperatures then the FT
will be different for the two measurements
- Use of synchrotron radiation If the measurement was carried out on a synchrotron, then the
polarisation correction is different (ie = 1) for both reflections and the ratio will be different
from the laboratory measurement.
- Detector non-linearity The 200 reflection is more intense than the 111, if this is sufficeient to saturate
the detector, then the measured intensity ratio will be incorrect.