Noreen Hanif
ASSIGNMENT 3

1. Calculation of F2 for

NaCl
a = 5.638 Å

Na (0,0,0) (0,1/2,1/2) (1/2,0,1/2) (1/2,1/2,0)
Cl (1/2,0,0) (0,1/2,0) (0,0,1/2) (1/2,1/2,1/2)

Structure factor equation :

                  F(S)  =   
å
n
fn e2p i (hx + ky + lz)

NaCl cubic hence
dhkl = a/(h2+k2+l2)1/2

(i) 200 reflection :

d200 = 5.638/(22+02+l0)1/2
d200 = 2.819 Å

Braggs Law : l = 2dsinq
sinq/l = 1/2d = 1/2(2.819) = 0.177 Å-1

From International Crystallographic Tables :

sinq/l0.150.2
fNa+9.0358.39
fCl-14.1212.2

Use intermediate values weighted towards the 0.2 value by 0.027:0.023, hence

sinq/l0.150.1770.2
fNa+9.0358.698.39
fCl-14.1213.0812.2


Comment: Correct.
5 Marks

cosine of F200 :
f8cos{360(hx+ky+lz)}
=8.69cos{360(2x0 + 0x0 + 0x0)}
+8.69cos{360(2x0 + 0x1/2 + 0x1/2)}
+8.69cos{360(2x1/2 + 0x0 + 0x1/2)}
+8.69cos{360(2x1/2 + 0x1/2 + 0x1/2)}
+13.08cos{360(2x1/2 + 0x0 + 0x0)}
+13.08cos{360(2x0 + 0x1/2 + 0x1/2)}
+13.08cos{360(2x0 + 0x0 + 0x1/2)}
+13.08cos{360(2x1/2 + 0x1/2 + 0x1/2)}
=8.69cos0 + 8.69cos0 + 8.69cos360 +8.69cos360 + 13.08cos360 + 13.08cos0 + 13.08cos0 + 13.08cos360
=8.69+8.69+8.69+8.69+13.0+813.08+813.08+813.08
= 87.08

sine part of F200 :
f8sin{360(hx+ky+lz)}
=8.69sin{360(2x0 + 0x0 + 0x0)}
+8.69sin{360(2x0 + 0x1/2 + 0x1/2)}
+8.69sin{360(2x1/2 + 0x0 + 0x1/2)}
+8.69sin{360(2x1/2 + 0x1/2 + 0x1/2)}
+13.08sin{360(2x1/2 + 0x0 + 0x0)}
+13.08sin{360(2x0 + 0x1/2 + 0x1/2)}
+13.08sin{360(2x0 + 0x0 + 0x1/2)}
+13.08sin{360(2x1/2 + 0x1/2 + 0x1/2)}
=8.69sin0 + 8.69sin0 + 8.69sin360 + 8.69sin360 + 13.08sin360 + 13.08sin0 + 13.08sin0 + 13.08sin360
= 0

F200 = 87.08 + i.0

Intensity I200 = F2002 = 7583 units


Comment: Correct.
5 Marks

(ii) 100 reflection

d100 = 5.638/(12+02+l0)1/2
d100 = 5.638 Å

Braggs Law : l = 2dsinq
sinq/l = 1/2d = 1/2(5.638) = 0.089 Å-1

cosine of F100 :
fNa+cos{360(hx+ky+lz)}
=fNa+cos{360(1x0 + 0x0 + 0x0)}
+fNa+cos{360(1x0 + 0x1/2 + 0x1/2)}
+fNa+cos{360(2x1/2 + 0x0 + 0x1/2)}
+fNa+cos{360(1x1/2 + 0x1/2 + 0x1/2)}
+fCl-cos{360(1x1/2 + 0x0 + 0x0)}
+fCl-cos{360(1x0 + 0x1/2 + 0x1/2)}
+fCl-cos{360(1x0 + 0x0 + 0x1/2)}
+fCl-cos{360(1x1/2 + 0x1/2 + 0x1/2)}
=fNa+cos0 + fNa+cos0 + fNa+cos180 + fNa+cos180 + fCl-cos180 + fCl-cos0 + fCl-cos0 + fCl-cos180
=fNa++fNa++(-fNa+)+(-fNa+)+(-fCl-)+fCl-+fCl-+(-fCl-)
= 0

sine part of F100 :
fnsin{360(hx+ky+lz)}
=fNa+sin{360(1x0 + 0x0 + 0x0)}
+fNa+sin{360(1x0 + 0x1/2 + 0x1/2)}
+fNa+sin{360(1x1/2 + 0x0 + 0x1/2)}
+fNa+sin{360(1x1/2 + 0x1/2 + 0x1/2)}
+fCl-sin{360(1x1/2 + 0x0 + 0x0)}
+fCl-sin{360(1x0 + 0x1/2 + 0x1/2)}
+fCl-sin{360(1x0 + 0x0 + 0x1/2)}
+fCl-sin{360(1x1/2 + 0x1/2 + 0x1/2)}
=fNa+sin0 + fNa+sin0 + fNa+sin180 + fNa+sin180 + fCl-sin180 + fCl-sin0 + fCl-sin0 + fCl-sin180
= 0

No intensity for reflection 100 due to systematic absence. Certain reflections for fcc structures are always forbidden such as the 100.


Comment: Correct answer and basically correct explanation.
6 Marks

2. Multiplicity allowance factor for 200 reflection:
2,0,0; -2,0,0
multiplicity j200 is 2.


Comment: The logic is correct as far as putting h=2 or h=-2; however being cubic, the other two axes are identical so 020, 0-20, 002, 00-2 are also permissable giving a final multiplicity of 6.
1 Mark

3. Polarisation allowance factor needed for 200 reflection :
Angles q, 2q
d200 = a/a/(h2+k2+l2)1/2
= 2.819 Å
Cu Ka wavelength is 1.54 Å
l = 2dsinq
1.54=2x2.819xsinq
q=15.85°, 2q=31.7°

P200 :
2q=31.7°
cos2q=0.8508
cos2(2q)=0.7239
1+cos2(2q)=1.7239
P200=1+cos2(2q)/2=0.862

Polarisation produces a 86.2% reduction in intensity for the 200 reflection.


Comment: Correct.
4 Marks

4. Lorentz allowance factor for 200 reflection :
From question 3, q=15.85°
sinq=0.273
sin2q=0.075
cosq=0.962
sin2qcosq=0.072

L200=1/(sin2qcosq)=1/0.072=13.89


Comment: Correct answer; I'd advise keeping to at least 3 figure accuracy everywhere in this context.
2.5 Marks

5. Ihkl=cjhklPhklLhklAFhkl2

The constant c disappears due to division when finding the ratio between the intensities. Consider experimental measurements of I111 and I200 identical and ignore A. Values for 111 reflection taken from notes.

I111/I200=(j111P111L111F1112) / (j200P200L200F2002)
=(8x0.894x18.39x398) / (2x0.862x13.89x7583)
=52347/181585
=0.288

Prediction of intensity ratio I111/I200=0.288


Comment: The method is correct but of course you are carrying a wrong value (2) for the multiplicity (6) so the actual numerical result obtained (0.288) is too large by a factor of 3.
3 Marks

6.
(i) Sample preparation : NaCl may not have been ground to a fine or even powder causing a poor powder average and differences in peak intensities.


2 Marks

(ii) Sample holder : if measurement made in transmission geometry and flat plate holders have been used then there will be a risk of preferred orientation causing differences in peak intensity. In capillary holders the cubic crystals may also align.


Comment: Correct; I would personally always put this as my No.1 suspicion, especially with flat plate as you point out, though in practice capillary with spinning is usually reliable.
2 Marks

(iii) Temperature effects : the temperature of the experiment needs to be considered which changes intensity.


Comment: This simple calculation of structure factor has ignored the atomic displacement parameters which are a function of Bragg angle and temperature. You need to be more specific here.
1 Mark

(iv) Position of X-ray beam : the beam should be falling on the same area of the sample so data obtained is from a constant area of the sample. This is important if the surface of the sample in a flat-plate holder is not smooth or well packed.


Comment: Yes since the beam footprint will change with angle.
1 Mark

(v) Damaged X-ray filter : beam non-monochromatic causing diffraction of different wavelengths which may interfere with the 111 and 200 reflections.


Comment: Interesting idea, but very unlikely.

(vi) Count time : not known if the instrument is a step-scanning diffractometer or has a stationary detector. Need to optimise the time over which the data is collected for either technique.


Comment: But the count time would have to be altered differently for the two peaks and its not obvious that this would happen from the circumstances you describe.

(vii) Sample spinning : if the instrument is a flat-plate Bragg Brentano diffractometer it may not have a facility for spinning the sample , therefore problems with sample averaging and texture may cause problems with peak intensity.


Comment: Correct, though I have bracketed this answer with your No.(i).
1 Mark

(viii) Background radiation : scattering of X-rays, e.g. air, other than Bragg reflection not accounted for.


Comment: I think this would be negligible since any such effect is small to begin with and is not going to vary dramatically with angle.

(ix) Crystallinity and phase purity : sample of NaCl not pure or crystalline will create difference in peak intensity.


Comment: Yes, NaCl could be impure. NaCl is always crystalline, though crystallinity can be a problem with some samples.
1 Mark

(x) Detector not calibrated : if the instrument is fitted with a position sensitive detector then it's calibration is required regularly so peak intensities can be reliably determined.


Comment: I agree that the detector status is important, whatever type of detector is used, but it requires a specific type of mal-function (such as a non-linearity or saturation) to cause a different type of change for the two peaks and thereby show up in the ratio.
0.5 Mark


Total: 8.5 Marks overall for this part


Comment: A very good assignment. Note the mistake in the multiplicity value propagated an error into the later value.